Call Us
+91-7486855455Send Us Mail
info@positronicsindia.comPositronics provides complete PLC & SCADA solutions, for in-plant and wide area applications, based on a variety of communication media. • Typically, data from plant-connected sensors are collected either in form of instrument signals or in form of digital communication. • SCADA software packages which Positronics is giving is `WinCC`, a product from SIEMENS.
Manufacture of Instrument, Electrical and Control panels is undertaken by experienced and skilled technicians, for both Safe area application and Hazardous Area application. All manufacturing activities are closely monitored and controlled by experienced engineers/supervisors..
Positronics provides comprehensive support for the systems that it supplies and also undertakes support of third party equipment and systems. Typically, a support contract will provide for preventive/corrective maintenance with guaranteed response times.
All of the company’s activities are subject to quality assurance under our Quality Management System, which is accredited to ISO-9001: 2015.
Fabrication, Removal of old instruments & installation of new, if required we also modify the cut outs suitable to new instruments Painting of existing old panels / JBs with proper surface finish with Epoxy/PU spray painting Wiring modification, ferrule replacements in existing old panels Loop checking and preparation of drawings of old existing panels Providing canopy (S.S., M.S., FRP) on existing panels/ JBs Testing & repairing/replacement of purge system in existing old panels and achieving required purge pressure Support for site supervision, Loop checking, Panel power up & commissioning S.S Tubing work for field instruments like Transmitter, skid, gauge, etc.... Replacement of old panels and installed new panel in same place or preparation of existing wiring details and termination drawings. Software development, logic modification in existing PLC system & HMI ( Siemens, Allen Bradley, Schneider, etc.... )
'Positronics' is a pioneer in developing PLC based Control System for High Pressure CNG/Gas Compressor & Turbines. The compressor is utilized to compress the incoming gas supply from low pressure to high pressure varying from 299 to 400 kg/cm2. The complete control system is protected in a flameproof/pressurized chamber of Gas Group IIA, IIB or IIC. depending on the requirements/applications. The PLC systems we provide can be operated with or without man and machine interface (MMI).
Water Supply Control & Instrumentation Management has been a forte of Positronics for the last twenty five years. We have executed more than two hundred projects in this area and have achieved an unmatched engineering expertise in this field. The instrumentation is mainly related to Monitoring & Control of Pressure, Level, Flow & Temperature.
Positronics offers a PLC based SCADA system solution for various stand alone and network systems for plant-wise applications in process industries. Man-Machine Interface (MMI) is a specific software package and is the heart of the system, based on an industrial standard Desktop Personal Computer. It offers graphical tools needed to compile various inter-related windows to suit the process operation application. The system is available in redundant or non-redundant configuration, depending on the requirement.
Pressurized purged panel system follows the basic principle of Exp (pressurized) protection used for Zone 1 and Zone 2 areas. This system provides the safest, reliable, maintenance friendly and most economical means of protection for hazardous area locations. The panels conform to NFPA-496 and IEC 60079-2. The in house expertise caters to such custom built panels for various applications and various sizes. Positronics has supplied more than 500 pressurized purged panels in various industries like petrochemicals, Fertilizers, Oil & Gas
Electrical supply is a key input in all industries & segments. Positronics designs & manufactures all types of Power Control Centers (PCC), Motor Control Junction Boxes for various process industries up to. 5000 amp. capacity. The panels are type tested for short circuit capacity of 50 KA for 1 sec & temperature rise test, as per IS:8623
LT PCC UPTO 6300A FIXED TYPE
LT MCC UPTO 6300A FIXED TYPE
LT BUSDUCTS 4000/5000A
LT DISTRIBUTION BOARDS
SYNCHRONIZING PANELS
AUTO-MANUAL CHANGEOVER PANELS
AUTOMATIC POWER FACTOR CORRECTION PANELS
HEAT TRACING LOCAL DISTRIBUTION BOARDS
LT BREAKER PANELS
HT JUNCTION BOX
FRP JUNCTION BOX
R.T.C.C.
COOLER CONTROL
LT MCC upto 3200A DRAW OUT
LIGHTING CONTROL PANEL WITH FRP CLOSURE
RTCC REMOTE TAP CHANGER CONTROL PANEL (RTCC FOR TRANSFORMER)
COOLER CONTROL > MARSHALLING BOX/ FAN CONTROL PANEL FOR TRANSFORMER
LT PCC UPTO 6300A FIXED TYPE
LT MCC UPTO 6300A FIXED TYPE
LT BUSDUCTS 4000/5000A
LT DISTRIBUTION BOARDS
SYNCHRONIZING PANELS
AUTO-MANUAL CHANGEOVER PANELS
AUTOMATIC POWER FACTOR CORRECTION PANELS
HEAT TRACING LOCAL DISTRIBUTION BOARDS
LT BREAKER PANELS
HT JUNCTION BOX
FRP JUNCTION BOX
R.T.C.C.
COOLER CONTROL
LT MCC upto 3200A DRAW OUT
LIGHTING CONTROL PANEL WITH FRP CLOSURE
RTCC REMOTE TAP CHANGER CONTROL PANEL (RTCC FOR TRANSFORMER)
COOLER CONTROL > MARSHALLING BOX/ FAN CONTROL PANEL FOR TRANSFORMER
LT DISTRIBUTION BOARDS > INDOOR/OUTDOOR DISTRIBUTION BOARDS
FEEDER PILLAR
AMF, SYNC. PANELS
MINI PILLARS
BMK, CT, CVT JB’s
LT DISTRIBUTION BOXES
ACDB, DCDB, LIGHTING PANELS